Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42.379
Filtrar
1.
Eur J Med Res ; 29(1): 244, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643140

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common cardiac arrhythmia worldwide. Catheter ablation has become a crucial treatment for AF. However, there is a possibility of atrial fibrillation recurrence after catheter ablation. Our study sought to elucidate the role of lncRNA‒mRNA regulatory networks in late AF recurrence after catheter ablation. METHODS: We conducted RNA sequencing to profile the transcriptomes of 5 samples from the presence of recurrence after AF ablation (P-RAF) and 5 samples from the absence of recurrence after AF ablation (A-RAF). Differentially expressed genes (DEGs) and long noncoding RNAs (DE-lncRNAs) were analyzed using the DESeq2 R package. The functional correlations of the DEGs were assessed through Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) analyses. A protein‒protein interaction (PPI) network was constructed using STRING and Cytoscape. We also established a lncRNA‒mRNA regulatory network between DE-lncRNAs and DEGs using BEDTools v2.1.2 software and the Pearson correlation coefficient method. To validate the high-throughput sequencing results of the hub genes, we conducted quantitative real-time polymerase chain reaction (qRT‒PCR) experiments. RESULTS: A total of 28,528 mRNAs and 42,333 lncRNAs were detected. A total of 96 DEGs and 203 DE-lncRNAs were identified between the two groups. GO analysis revealed that the DEGs were enriched in the biological processes (BPs) of "regulation of immune response" and "regulation of immune system process", the cellular components (CCs) of "extracellular matrix" and "cell‒cell junction", and the molecular functions (MFs) of "signaling adaptor activity" and "protein-macromolecule adaptor activity". According to the KEGG analysis, the DEGs were associated with the "PI3K-Akt signaling pathway" and "MAPK signaling pathway." Nine hub genes (MMP9, IGF2, FGFR1, HSPG2, GZMB, PEG10, GNLY, COL6A1, and KCNE3) were identified through the PPI network. lncRNA-TMEM51-AS1-201 was identified as a core regulator in the lncRNA‒mRNA regulatory network, suggesting its potential impact on the recurrence of AF after catheter ablation through the regulation of COL6A1, FGFR1, HSPG2, and IGF2. CONCLUSIONS: The recurrence of atrial fibrillation after catheter ablation may be associated with immune responses and fibrosis, with the extracellular matrix playing a crucial role. TMEM51-AS1-201 has been identified as a potential key target for AF recurrence after catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , MicroRNAs , RNA Longo não Codificante , Humanos , RNA Longo não Codificante/genética , Redes Reguladoras de Genes , Fibrilação Atrial/genética , Fibrilação Atrial/cirurgia , RNA Mensageiro/genética , Fosfatidilinositol 3-Quinases , MicroRNAs/genética
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38582974

RESUMO

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Assuntos
Cardiomiopatias , Ablação por Cateter , Criocirurgia , Taquicardia Ventricular , Idoso , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/complicações , Criocirurgia/efeitos adversos , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Temperatura , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584521

RESUMO

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Doença Iatrogênica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ablação por Cateter/efeitos adversos , Falha de Prótese , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Agulhas , Função Ventricular Esquerda , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Angiografia Coronária
4.
Sci Rep ; 14(1): 8974, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637577

RESUMO

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Telas Cirúrgicas , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Arritmias Cardíacas , Resultado do Tratamento
5.
J Am Heart Assoc ; 13(8): e033740, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38597139

RESUMO

BACKGROUND: Periodontitis has not been recognized as a modifiable risk factor for atrial fibrillation (AF). This prospective nonrandomized study investigated whether periodontal treatment improves the AF ablation outcome. METHODS AND RESULTS: We prospectively enrolled 288 AF patients scheduled to undergo initial radiofrequency catheter ablation. Each patient underwent periodontal inflamed surface area (PISA; a quantitative index of periodontal inflammation) measurement. All eligible patients were recommended to receive periodontal treatment within the blanking period, and 97 consented. During the mean follow-up period of 507±256 days, 70 (24%) AF recurrences were documented. Patients who exhibited AF recurrences had a higher PISA than those who did not (456.8±403.5 versus 277.7±259.0 mm2, P=0.001). These patients were categorized into high-PISA (>615 mm2) and low-PISA (<615 mm2) groups according to the receiver operating characteristic analysis for AF recurrence (area under the curve, 0.611; sensitivity, 39%; specificity, 89%). A high PISA, as well as female sex, AF duration, and left atrial volume, were the statistically significant predicter for AF recurrence (hazard ratio [HR], 2.308 [95% CI, 1.234-4.315]; P=0.009). In patients with a high PISA, those who underwent periodontal treatment showed significantly fewer AF recurrences (P=0.01, log-rank test). The adjusted HR of periodontal treatment for AF recurrence was 0.393 (95% CI, 0.215-0.719; P=0.002). CONCLUSIONS: Periodontitis may serve as a modifiable risk factor for AF. PISA is a hallmark of AF recurrence, and periodontal treatment improves the AF ablation outcome, especially for those with poor periodontal condition.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Periodontite , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Recidiva , Resultado do Tratamento
8.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563835

RESUMO

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Compostos Organotiofosforados , Veias Pulmonares , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Teorema de Bayes , Estudos Prospectivos , Veias Pulmonares/cirurgia , Ablação por Cateter , Cateterismo
9.
Skin Res Technol ; 30(4): e13652, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572582

RESUMO

OBJECTIVE: To investigate whether compression therapy after thermal ablation of varicose veins can improve the prognosis of patients. METHODS: Systematic research were applied for Chinese and English electronic databases(PubMed, Web of Science, Cochrane Library, CNKI, Wanfang, VIP Databases). Eligible prospective studies that comparing the efficacy of compression therapy and non-compression therapy on patients after thermal ablation of varicose veins were included. The interest outcome such as pain, quality of life (QOL), venous clinical severity score (VCSS), time to return to work and complications were analyzed. RESULTS: 10 studies were of high quality, and randomized controlled trials involving 1,545 patients met the inclusion criteria for this study. At the same time, the meta-analysis showed that the application of compression therapy improved pain (SMD: -0.51, 95% CI: -0.95, -0.07) but exhibited no statistically significant effect on QOL (SMD: 0.04, 95% CI: -0.08, 0.16), VCSS (MD: -0.05, 95% CI: -1.19, 1.09), time to return to work (MD: -0.43, 95% CI: -0.90, 0.03), total complications (RR: 0.54, 95% CI: 0.27, 1.09), and thrombosis (RR: 0.71, 95% CI: 0.31, 1.62). CONCLUSION: Compression therapy after thermal ablation of varicose veins can slightly relieve pain, but it has not been found to be associated with improvement in other outcomes.


Assuntos
Ablação por Cateter , Terapia a Laser , Varizes , Humanos , Qualidade de Vida , Estudos Prospectivos , Terapia a Laser/métodos , Varizes/cirurgia , Varizes/etiologia , Dor/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
JACC Clin Electrophysiol ; 10(4): 685-694, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38658060

RESUMO

BACKGROUND: Reconnection after mitral isthmus (MI) block with radiofrequency ablation is common. OBJECTIVES: The aim of this study was to investigate the effects of ethanol infusion in the vein of Marshall (EIVOM) on acute reconnection after MI bidirectional block. METHODS: Patients with persistent atrial fibrillation who were scheduled to receive radiofrequency ablation for the first time were randomly assigned to the radiofrequency catheter ablation (RFCA) group (n = 44) or the EIVOM group (n = 45). The RFCA group's strategy was bilateral pulmonary vein ablation and linear ablation; in the EIVOM group, EIVOM was performed first. The primary endpoint was acute reconnection 30 minutes after MI bidirectional block. RESULTS: A total of 89 patients (average age 62.9 years; 57.3% male) were enrolled. The average duration for persistent atrial fibrillation was 2.3 years. Before observation, all patients in the EIVOM group achieved MI bidirectional block (45 of 45 [100%]), compared with 84.1% (37 of 44) in the RFCA group. After the observation, 3 cases of MI reconnection occurred in the EIVOM group and 13 cases in the RFCA group (6.7% vs 35.1%; P < 0.05). After additional ablation, the final MI block rates in the EIVOM and RFCA groups were 97.8% (44 of 45) and 72.7% (32 of 44), respectively. During a 1-year follow-up, 8 of 45 patients who underwent EIVOM had recurrent atrial fibrillation, compared with 14 of 44 in the RFCA group (17.8% vs 31.8%; P < 0.01). CONCLUSIONS: EIVOM can reduce acute reconnection after MI bidirectional block and significantly increase first-pass MI block.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Valva Mitral , Veias Pulmonares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Valva Mitral/cirurgia , Veias Pulmonares/cirurgia , Etanol/administração & dosagem , Recidiva , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 47(5): 614-625, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38558218

RESUMO

INTRODUCTION: The use of esophageal temperature monitoring (ETM) for the prevention of esophageal injury during atrial fibrillation (AF) ablation is often advocated. However, evidence supporting its use is scarce and controversial. We therefore aimed to review the evidence assessing the efficacy of ETM for the prevention of esophageal injury. METHODS: We performed a meta-analysis and systematic review of the available literature from inception to December 31, 2022. All studies comparing the use of ETM, versus no ETM, during radiofrequency (RF) AF ablation and which reported the incidence of endoscopically detected esophageal lesions (EDELs) were included. RESULTS: Eleven studies with a total of 1112 patients undergoing RF AF ablation were identified. Of those patients, 627 were assigned to ETM (56%). The overall incidence of EDELs was 9.8%. The use of ETM during AF ablation was associated with a non significant increase in the incidence of EDELs (12.3% with ETM, vs. 6.6 % without ETM, odds ratio, 1.44, 95%CI, 0.49, 4.22, p = .51, I2 = 72%). The use of ETM was associated with a significant increase in the energy delivered specifically on the posterior wall compared to patients without ETM (mean power difference: 5.13 Watts, 95% CI, 1.52, 8.74, p = .005). CONCLUSIONS: The use of ETM does not reduce the incidence of EDELs during RF AF ablation. The higher energy delivered on the posterior wall is likely attributable to a false sense of safety that may explain the lack of benefit of ETM. Further randomized controlled trials are needed to provide conclusive results.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/prevenção & controle , Esôfago/lesões , Temperatura Corporal , Monitorização Intraoperatória/métodos , Complicações Intraoperatórias/prevenção & controle
13.
J Cardiothorac Surg ; 19(1): 205, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615019

RESUMO

BACKGROUND: To date, the extended Morrow procedure is considered the gold standard treatment for patients with obstructive hypertrophic cardiomyopathy who experience severe symptoms and are unresponsive to medication treatment. We therefore aimed to perform transapical intramyocardial septal microwave ablation to reduce the thickness of the interventricular septum myocardium in a minimally invasive method. METHODS: Fourteen swine were divided to form either a microwave ablation group (n = 7) or a sham group (n = 7). In the microwave ablation group, a transapical microwave antenna was inserted into the septum to ablate each myocardial segment at 40 W for 1 min, while in the sham group, the same operation was performed but without power output. We used echocardiography, electrocardiogram, during the operation. And added computerized tomography, cardiac nuclear magnetic resonance during follow-up. RESULTS: Segment hypokinesis was observed in all swine immediately following ablation. Compared with the sham group, the thickness of ablated segments in the ablation group decreased significantly 1 month post-operation (ablation group, 5.53 ± 1.00 mm vs. 8.03 ± 1.15 mm, respectively, P < 0.01; sham group, 8.40 ± 0.94 mm vs. 8.21 ± 1.09 mm, respectively, P = 0.081), and the outcome was still observed 1 year post-operation (ablation group, 3.36 ± 0.85 mm vs. 8.03 ± 1.15 mm, respectively, P < 0.01). No perforation of the septum was observed during the procedure or follow-up, and no heart failure or sudden cardiac death occurred during postoperative feeding. CONCLUSIONS: Transapical intramyocardial septal microwave ablation can effectively and safely produce a large region of necrosis. This technique can potentially mimic surgical myectomy while avoiding cardiopulmonary bypass and median sternotomy in high-risk hypertrophic obstructive cardiomyopathy patients.


Assuntos
Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Animais , Suínos , Micro-Ondas/uso terapêutico , Cardiomiopatia Hipertrófica/cirurgia , Coração , Miocárdio
14.
BMC Cancer ; 24(1): 481, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627695

RESUMO

BACKGROUND: The treatment for lung oligometastasis from colorectal cancer (CRC) remains challenging. This retrospective study aimed to compare the local tumor control, survival and procedure-related complications in CRC patients undergoing low-dose rate stereotactic ablative brachytherapy (L-SABT) versus percutaneous microwave ablation (MWA) for lung oligometastasis. METHODS: Patients between November 2017 and December 2020 were retrospectively analyzed. Local tumor progression-free survival (LTPFS) and overall survival (OS) were analyzed in the entire cohort as well as by stratified analysis based on the minimal ablation margin (MAM) around the tumor. RESULTS: The final analysis included 122 patients: 74 and 48 in the brachytherapy and MWA groups, respectively, with a median follow-up of 30.5 and 35.3 months. The 1- and 3-year LTPFS rate was 54.1% and 40.5% in the brachytherapy group versus 58.3% and 41.7% in the MWA group (P = 0.524 and 0.889, respectively). The 1- and 3-year OS rate was 75.7% and 48.6% versus 75.0% and 50.0% (P = 0.775 and 0.918, respectively). Neither LTPFS nor OS differed significantly between the patients with MAM of 5-10 mm versus > 10 mm. Pulmonary complication rate did not differ in the overall analysis, but was significantly higher in the MWA group in the subgroup analysis that only included patients with lesion within 10 mm from the key structures (P = 0.005). The increased complications was primarily bronchopleural fistula. CONCLUSIONS: Considering the caveats associated with radioisotope use in L-SABT, MWA is generally preferable. In patients with lesion within 10 mm from the key pulmonary structures, however, L-SABT could be considered as an alternative due to lower risk of bronchopleural fistula.


Assuntos
Braquiterapia , Ablação por Cateter , Neoplasias Colorretais , Fístula , Neoplasias Hepáticas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Estudos Retrospectivos , Terapia de Salvação , Micro-Ondas/efeitos adversos , Braquiterapia/efeitos adversos , Resultado do Tratamento , Pulmão/patologia , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/cirurgia , Fístula/cirurgia , Neoplasias Hepáticas/cirurgia
15.
Front Endocrinol (Lausanne) ; 15: 1355383, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628591

RESUMO

Purpose: Radiofrequency ablation (RFA) is an effective and safe modality for the treatment of thyroid nodules. Nodule rupture is a major complication of RFA. There is little known on the natural history of nodule rupture due to a lack of clinical experience and no consensus on its management. A comprehensive review of nodule rupture presentation, diagnosis, and management is needed. Methods: We report a case of nodule rupture and conduct a literature review. A total of 33 patients experiencing nodule rupture after RFA were included, and their clinical presentation, management, and outcomes were collected and analyzed. Results: Nodule rupture presents with acute swelling (90.3%) and pain (77.4%) within 7 months of RFA procedure, most commonly due to disruption of the anterior thyroid capsule (87%), and can be diagnosed with ultrasonography. Most ruptures can be managed conservatively, exemplified by our reported case. There are no reported cases of long-term sequalae. Conclusion: Nodule rupture is the second most common major complication of RFA. Based on the available evidence, we propose a treatment algorithm for nodule rupture and recommendations for future data collection to address gaps in our understanding of rupture etiology and effective management.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/métodos
16.
J Cardiothorac Surg ; 19(1): 238, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632637

RESUMO

BACKGROUND: There is insufficient information regarding the bleeding sites and surgical strategies of cardiac tamponade during catheter ablation for atrial fibrillation (AF). CASE PRESENTATION: Of the five patients with cardiac tamponade, three required surgical intervention and two required pericardiocentesis. In the first case of three cardiac tamponades requiring surgical intervention, considering that the peripheral route was used, the catecholamines did not reach the heart, and due to unstable vital signs, venoarterial extracorporeal membrane oxygenation (VA-ECMO) was inserted. No bleeding point was identified, but a thrombus had spread around the left atrium (LA) with diverticulum. Hemostasis was achieved with adhesives placed around the LA under on-pump beating. In the second case, pericardiocentesis was performed, but the patient showed heavy bleeding and unstable vital signs. Thus, VA-ECMO was inserted. Heavy bleeding was expected, and safety was enhanced by attaching a reservoir to the VA-ECMO. The bleeding point was found between the left upper pulmonary artery and LA under cardiac arrest to obtain a good surgical view for suturing repair. In the third case, the LA diverticulum was damaged. Pericardiocentesis resulted in stable vitals, but sustained bleeding was present. A bleeding point was found at the LA diverticulum, and suture repair under on-pump beating was performed. CONCLUSIONS: When cardiac tamponade occured in any patient with LA diverticulum, treatment could not be completed with pericardiocentesis alone, and thoracotomy was likely to be necessary. If the bleeding point could be confirmed, suturing technique is a more reliable surgical strategy than adhesive alone that leads to pseudoaneurysm. If the bleeding point is unclear, it is important to confirm the occurrence of LA diverticulum using a preoperative CT, and if confirmed, cover it with adhesive due to a high possibility of diverticulum bleeding. The necessity of CPB should be determined based on whether these operations can be completed while maintaining vital stability.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Divertículo , Humanos , Tamponamento Cardíaco/cirurgia , Toracotomia , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia , Hemorragia/etiologia , Ablação por Cateter/métodos , Divertículo/cirurgia , Resultado do Tratamento
17.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38652090

RESUMO

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Tomografia Computadorizada Multidetectores , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Idoso , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Recidiva , Frequência Cardíaca , Potenciais de Ação
18.
Pacing Clin Electrophysiol ; 47(5): 653-660, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38583088

RESUMO

Atrial tachycardia (AT) is a common rhythm disorder, especially in patients with atrial structural abnormalities. Although voltage mapping can provide a general picture of structural alterations which are mainly secondary to prior ablations, surgery or pressure/volume overload, data is scarce regarding the functional characteristics of low voltage regions in the atrium to predict critical isthmus of ATs. Recently, functional substrate mapping (FSM) emerged as a potential tool to evaluate the functionality of structurally altered regions in the atrium to predict critical sites of reentry. Current evidence suggested a clear association between deceleration zones of isochronal late activation mapping (ILAM) during sinus/paced rhythm and critical isthmus of reentry in patients with left AT. Therefore, these areas seem to be potential ablation targets even not detected during AT. Furthermore, abnormal conduction detected by ILAM may also have a role to identify the potential substrate and predict atrial fibrillation outcome after pulmonary vein isolation. Despite these promising findings, the utility of such an approach needs to be evaluated in large-scale comparative studies. In this review, we aimed to share our experience and review the current literature regarding the use of FSM during sinus/paced rhythm in the prediction of re-entrant ATs and discuss future implications and potential use in patients with atrial low-voltage areas.


Assuntos
Átrios do Coração , Humanos , Átrios do Coração/fisiopatologia , Cicatriz/fisiopatologia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos
19.
Medicine (Baltimore) ; 103(14): e37723, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579029

RESUMO

INTRODUCTION: Transseptal punctures (TSPs) are widely used in left atrium and left ventricle surgery. Accidental puncture of the puncture needle into the aorta is a rare complication that is rarely reported but has serious consequences. The appropriate management of this complication remains unclear. PATIENT CONCERNS: This report describes a case of a male with the chief complaint: paroxysmal palpitation for 1 year, aggravated for 1 month. DIAGNOSIS: The electrophysiological diagnosis was atrioventricular reentrant tachycardia caused by left-side bypass. INTERVENTIONS: Radiofrequency ablation of the heart was a necessary treatment and a TSP operation was needed, in which a puncture was mistakenly believed to have entered the aorta, a series of measures were taken urgently. Although the surgical procedure in this case was a false alarm, we still initiated a series of emergency plans. Emergency measures to address the complications were effectively implemented, and the emergency measures were promptly terminated after it was clear that complications had been misjudged. OUTCOMES: At last, it was confirmed that the angiogram was a pulmonary artery image, not an aorta image. Then the atrial septal puncture operation was successfully completed, and under the guidance of the Carto system, the ablation was successfully completed. Postoperative fluoroscopy showed no complications, such as pericardial effusion. After 2 years of follow-up, there was no reoccurrence of tachycardia, and there were no complications. It is crucial that emergency procedures are terminated in a timely manner after a clear miscarriage of performance. Although accidental puncture into the aorta is urgent and serious, performing a blockage or even thoracotomy in an emergency if complications are not clearly confirmed can cause further damage to the patient and would be a definitively wrong strategy. CONCLUSION: Strict and standardized TSP operations can avoid complications. Correct judgment of the authenticity of complications is crucial, and remedial measures that may cause further damage should not be blindly adopted. The retention of the aortic guide wire can provide convenient access for further differential diagnosis and remedial treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Comunicação Interatrial , Ablação por Radiofrequência , Humanos , Masculino , Aorta/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Comunicação Interatrial/cirurgia , Punções/efeitos adversos , Punções/métodos , Resultado do Tratamento
20.
Zhonghua Gan Zang Bing Za Zhi ; 32(3): 208-213, 2024 Mar 20.
Artigo em Chinês | MEDLINE | ID: mdl-38584101

RESUMO

Objective: To investigate the spatial distribution pattern of local tumor progression (LTP) for hepatocellular carcinoma (HCC) ≤5 cm after microwave ablation. Methods: A retrospective analysis was performed on 169 HCCs with matched MRI before and after ablation from December 2009 to December 2019. A tumor MRI was reconstructed using three-dimensional visualization technology. LTP was classified as contact or non-contact, early or late stage, according to whether LTP was in contact with the edge of the ablation zone and the occurrence time (24 months). The tumor-surrounded area was divided into eight quadrants by using the eight-quadrant map method. An analysis was conducted on the spatial correlation between the quadrant where the ablative margin (AM) safety boundary was located and the quadrant where different types of LTP occurred. The t-test, or rank-sum test, was used for the measurement data. 2-test for count data was used to compare the difference between the two groups. Results: The AM quadrant had a distribution of 54.4% LTP, 64.2% early LTP stage, and 69.1% contact LTP, suggesting this quadrant was much more concentrated than the other quadrants (P < 0.001). Additionally, the AM quadrant had only 15.2% of non-contact type LTP and 17.1% of late LTP, which was not significantly different from the average distribution probability of 12.5% (100/8%) among the eight quadrants (P = 0.667, 0.743). 46.6% of early contact type LTP was located at the ablation needle tip, 25.2% at the body, and 28.1% at the caudal, while the location distribution probabilities of non-early contact LTP were 34.8%, 31.8%, and 33.3%, respectively. Conclusion: LTP mostly occurs in areas where the ablation safety boundary is the shortest. However, non-contact LTP and late LTP stages exhibit the feature of uniform distribution. Thus, this type of LPT may result from an inadequate non-ablation safety boundary.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Imageamento Tridimensional/métodos , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...